Least count of micrometer screw gauge - Engistudies

Breaking

May 2, 2018

Least count of micrometer screw gauge

We have already discussed the details of Vernier Caliper least count. Here we will discuss another measurement instrument called 'Micrometer screw gauge'.

Least count of screw gauge is 0.01 mm.

How come?

The least count of any measuring instrument is the smallest change in the measured quantity that can be resolved on its scale. The equation to find out least count is,

L.C. = Minimum Main scale division / Total circular scale divisions

The diagram shows a metric micrometer and nomenclature of its parts.

Micrometer parts

0.5 mm is the min main scale division value and a circular scale is divided into 50 lines. We can now get the answer by dividing the values as per the above formula.

Least count of screw gauge = 0.5 / 50 = 0.01 mm

Note that:
  • Before taking the reading on micrometer check if it has any positive or negative zero error. If it does have then re-calibrate it.
  • Avoid directly rotating circular scale. Instead, use the ratchet to get fine measurements.
  • The part should be free from burr.

No comments:

Post a Comment